Medical Reusable Adult Finger Clip SpO2 Sensor Compatible with Philips 8p (MP20)

Get the Medical Reusable Adult Finger Clip SpO2 Sensor Compatible with Philips 8p (MP20) directly from our factory. Affordable and reliable solution.
Request a Quote

PRODUCTS DETAILS

  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
  • Certifications
  • Exhibition
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
J84S001B
Group
Adult
Name
Reusable SpO2 Sensor Probes for Philips
Properties
Medical Materials & Accessories
Usage
Blood Oxygen Saturation
Shelf Life
2 Years
Color
Grey
Transport Package
Single Bag
Specification
3 meter/custom
Trademark
JCR
Origin
Guangdong, China
HS Code
9018193090
Production Capacity
200000/Month

Product Description

Product Description

Reusable SpO2 Sensor Probes for Philips
Compatible Models NO. MP20 MP30 MP40 MP50 MP70 MP80 MP90 Masimo-

Product Name
Module Number
PH 12P Adult clip SPO2 sensor
J84S001B
PH 12P Adult soft SPO2 sensor
J84S002S
PH 12P Neonate wrap SPO2 sensor
J84S003E
Operation principle, function and structure
The patient sensor end of the product is clamped the patient's index fifinger with (Thumb, middle
fifinger or others, great toes), and the device connector is connected to compatible monitors or
oximeters with SpO2 extension cord. The product adopts 660nm red light and 905nm Infrared light as
incident light source, tests light intensity through tissue to obtain SpO2 value as well as pulse rate.

Specification

Measurement wavelengths and Output Power: Red:660±5 nm @ 2.0mw maximum average
Infrared: 905 nm±5 nm @ 2.0 mw maximum average Oxygen Saturation Declared
Accuracy Range: ±3% of 70%~79% spo2; ±2% of 80%~89% spo2; ±1% of 90%~100% spo2;
Pulse Rate Range: 30~245 BPM;
Accuracy: ±3%bpm of 150 bpm~245 bpm; ±2 bpm of 60 bpm~149 bpm; ±1% bpm of 30 bpm~59 bpm
Response Time: ≤30s
Product Parameters

Operation specification requirements and considerations

1)Please check if the packing is complete and not broken.
2)Turn the monitor ON prior to setting up the disposable pressuretransducer system.
3)Open the disposable pressure transducer kit package using sterile technique. Verify that all
connections are secure and all stopcock handles are good. Be careful to not over-tighten luer connections.
4)All side ports of stopcocks in monitoring kits are protected by vented caps which are to remain in place until the system is filled with sterile solution and dedubbled. These vented caps should always be replaced with non-vented caps provided in a separate pouch in each kit.
 
Detailed Photos

Medical Reusable Adult Finger Clip SpO2 Sensor Compatible with Philips 8p (MP20)Medical Reusable Adult Finger Clip SpO2 Sensor Compatible with Philips 8p (MP20)
Medical Reusable Adult Finger Clip SpO2 Sensor Compatible with Philips 8p (MP20)
Medical Reusable Adult Finger Clip SpO2 Sensor Compatible with Philips 8p (MP20)Medical Reusable Adult Finger Clip SpO2 Sensor Compatible with Philips 8p (MP20)Medical Reusable Adult Finger Clip SpO2 Sensor Compatible with Philips 8p (MP20)

Company Profile

Medical Reusable Adult Finger Clip SpO2 Sensor Compatible with Philips 8p (MP20)

Certifications

Medical Reusable Adult Finger Clip SpO2 Sensor Compatible with Philips 8p (MP20)

Exhibition

Medical Reusable Adult Finger Clip SpO2 Sensor Compatible with Philips 8p (MP20)

Packaging & Shipping

Medical Reusable Adult Finger Clip SpO2 Sensor Compatible with Philips 8p (MP20)

Medical Reusable Adult Finger Clip SpO2 Sensor Compatible with Philips 8p (MP20)

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours