Basic Info.
Model NO.
J00084
Group
Adult
Name
Reusable SpO2 Sensor Probes for Edan
Properties
Medical Materials & Accessories
Usage
Blood Oxygen Saturation
Shelf Life
2 Years
Color
Grey
Packing
Individual
Transport Package
Single Bag
Specification
3/5m
Trademark
JCR
Origin
Guangdong, China
HS Code
9018193090
Production Capacity
200000/Month
Product Description
Indications
The product is indicated for reuse to collect and transmit signal of SpO2 and pulse rate of patient,
with compatible monitors or oximeters. The product is only used by experienced medical professional
or under their directions.
with compatible monitors or oximeters. The product is only used by experienced medical professional
or under their directions.
Operation principle, function and structure
The patient sensor end of the product is clamped the patient's index fifinger with (Thumb, middle
fifinger or others, great toes), and the device connector is connected to compatible monitors or
oximeters with SpO2 extension cord. The product adopts 660nm red light and 905nm Infrared light as
incident light source, tests light intensity through tissue to obtain SpO2 value as well as pulse rate.
fifinger or others, great toes), and the device connector is connected to compatible monitors or
oximeters with SpO2 extension cord. The product adopts 660nm red light and 905nm Infrared light as
incident light source, tests light intensity through tissue to obtain SpO2 value as well as pulse rate.
Specification
Measurement wavelengths and Output Power | Red:660±5 nm @ 2.0mw maximum average |
Infrared | 905 nm±5 nm @ 2.0 mw maximum average Oxygen Saturation Declared |
Accuracy Range | ±3% of 70%~79% spo2; ±2% of 80%~89% spo2; ±1% of 90%~100% spo2; |
Pulse Rate Range | 30~245 BPM |
Accuracy | ±3%bpm of 150 bpm~245 bpm; ±2 bpm of 60 bpm~149 bpm; ±1% bpm of 30 bpm~59 bpm |
Response Time | ≤30s |
Operation specification requirements and considerations
1)Please check if the packing is complete and not broken.
2)Turn the monitor ON prior to setting up the disposable pressuretransducer system.
3)Open the disposable pressure transducer kit package using sterile technique. Verify that all
connections are secure and all stopcock handles are good. Be careful to not over-tighten luer connections.
4)All side ports of stopcocks in monitoring kits are protected by vented caps which are to remain in place until the system is filled with sterile solution and dedubbled. These vented caps should always be replaced with non-vented caps provided in a separate pouch in each kit.
3)Open the disposable pressure transducer kit package using sterile technique. Verify that all
connections are secure and all stopcock handles are good. Be careful to not over-tighten luer connections.
4)All side ports of stopcocks in monitoring kits are protected by vented caps which are to remain in place until the system is filled with sterile solution and dedubbled. These vented caps should always be replaced with non-vented caps provided in a separate pouch in each kit.