Basic Info.
Model NO.
E-SNP900N-03
Weight
4kg
Screen
12.1" High Resolution Color
Lithium Battery
14.8V 2200mAh
Parameters
ECG+SpO2+NIBP+Temp+Hr
Optional Parameters
Printer, CO2, 2-IBP
Plus
Touchscreen
Transport Package
Caton
Specification
30*28*15cm
Trademark
EMINENT
Origin
China
Production Capacity
1000pieces/Month
Product Description
Features &Benefits:
Patient range: Adult
- 12.1" color TFT display, high resolution: 800×600dpi;
- 6 in 1 para board: ECG, NIBP, SpO2 board;
- Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.
- Real time S-T segment analysis, and ARR analysis;
- SpO2 Pitch Tone Variation and Drug Dose Calculation;
- Parameter waveform and characters color selectable
- Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
- 7-lead ECG waveforms display in phase;
- Capture dynamic waveforms;
- Built-in rechargeable lithium battery, and battery volume checking,
- AC power checking
- Efficient resistance to interference of defibrillator and HF knife;
- SINNOR F-6 SpO2 technology
- Networking capacity and TCP/IP networking platform enable abundant future upgrade
- Time delay switch-off function keep the monitor data restart monitor;
- Complete and flexible mounting solution for transportation and in-patient monitoring
Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.
Optional: Touch Screen, Thermal Recorder, EtCO2, 2-IBP, Trolley/Wall mount
Maintenance inspection
Before using the monitor, the following inspections should be performed:
1. Check for any mechanical damage;
2. Check all exposed wires, inserts and accessories;
3. Check the function of all equipment that may be used to monitor the patient, and ensure that the equipment is in good working condition.
Every 6-12 months or after each maintenance, a comprehensive inspection of the equipment, including functional safety, must be carried out by qualified personnel.
Clean
General cleaning:
The monitor should be kept free of dust.
It is recommended to clean the outside of the case and the monitor screen. Use non-aggressive cleaners such as soap and water to clean the case.
Detergent:
With the exception of those listed in the "Caution" section, any solution that can be classified as one of the following products can be used as a cleaning agent:
1 Diluted ammonia water; 2 Diluted sodium hypochlorite (bleaching powder for washing); 3 Diluted formaldehyde 35~37%; 4 Diluted hydrogen peroxide 3%; 5 Ethanol; 6 Isopropanol.
Sterilize
To avoid long-term damage to equipment, we recommend sterilizing products only when deemed necessary in your hospital repair program. We also recommend that sterilized products be cleaned first.
Recommended germicidal materials for monitors: ethanol-based, acetaldehyde-based.