- Overview
- Product Description
- Company Profile
Basic Info.
Model NO.
CMS50D-1
Dimensions
60(L) mm *30.5(W) mm *32.5 (H) mm
Display Mode
0.96" Dual-Color Display
Power Supply
1.5 V (AAA Size) Alkaline Batteries ×
Function 1
Display of SpO2 Value,Pulse Rate Waveform
Function 2
Auto Power on, Auto Standby.
Indication
Low-Voltage Indication
Function 3
Capacity Pulse Scanning & Recording
Transport Package
Carton
Specification
60(L)mm*30.5(W)mm*32.5 (H)mm
Trademark
CONTEC
Origin
China
HS Code
9018909911
Production Capacity
10000/Week
Product Description
Contec Manufacturer CMS50D-1 Color Finger Pulse Oximeter Adult SPO2 Monitor Model:CMS50D2 Brand:CONTEC SCMS50D2-1 Pulse Oximeter is a non-invasive device intended for the spot-check of oxygen saturation of arterial hemoglobin (SpO2)and the pulse rate of adult and pediatric patients in home and hospital environments (including clinical use in internist/surgery, anesthesia, intensive care ect.). This device is not intended for continuous monitoring.
Features
SpO2 value display
PR value and bar graph display
PI value display(Optional)
Pulse waveform display
Low-battery indication: low-battery indication appears when
the battery voltage is too low to work
Battery electric power display
Automatic standby function
Display mode can be changed
Adjustable screen brightness
Display direction can be changed automatically
PR sound indication(Optional)
Voice prompt for over-limit(Optional)
Performance
Display Mode:0.96" color screen
SpO2Measuring Range:0%~100%, (the resolution is 19%).
Accuracy: 70%~100%:±2%,Below 70% unspecified.
PR Measuring Range:30 bpm ~250 bpm, (the resolution is 1 bpm)
Accuracy:±2 bpm or ±2% (select larger)
Pl measurement range(Optional):0%~20%
Accuracy: 1% ~ 20 %, allowable absolute error: ±1%;
0 % ~ 0.9 %, allowable absolute error: ±0.2%
Accuracy under low perfusion; low perfusion 0.4 %, SpO2 accuracy: ± 4 %; PR accuracy:±2 bpm or ± 2 %, whichever is greater.
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%
Power Consumption:≤30mA(without prompt sound); ≤80mA (with prompt sound)
Voltage:DC2.6V-3.6V
Battery working hour: Two batteries can work continually for 20 hours
Safety Type:Interior Battery,BF Type
Accessories
One hanging rope(optional)
Two batteries(optional)
One User Manual
Physical characteristic
Features
SpO2 value display
PR value and bar graph display
PI value display(Optional)
Pulse waveform display
Low-battery indication: low-battery indication appears when
the battery voltage is too low to work
Battery electric power display
Automatic standby function
Display mode can be changed
Adjustable screen brightness
Display direction can be changed automatically
PR sound indication(Optional)
Voice prompt for over-limit(Optional)
Performance
Display Mode:0.96" color screen
SpO2Measuring Range:0%~100%, (the resolution is 19%).
Accuracy: 70%~100%:±2%,Below 70% unspecified.
PR Measuring Range:30 bpm ~250 bpm, (the resolution is 1 bpm)
Accuracy:±2 bpm or ±2% (select larger)
Pl measurement range(Optional):0%~20%
Accuracy: 1% ~ 20 %, allowable absolute error: ±1%;
0 % ~ 0.9 %, allowable absolute error: ±0.2%
Accuracy under low perfusion; low perfusion 0.4 %, SpO2 accuracy: ± 4 %; PR accuracy:±2 bpm or ± 2 %, whichever is greater.
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%
Power Consumption:≤30mA(without prompt sound); ≤80mA (with prompt sound)
Voltage:DC2.6V-3.6V
Battery working hour: Two batteries can work continually for 20 hours
Safety Type:Interior Battery,BF Type
Accessories
One hanging rope(optional)
Two batteries(optional)
One User Manual
Physical characteristic
Dimensions | 60(L) mm X 32.5(W) mm X30.5 (H) mm |
Weight | About 50g (with the batteries) |