- Overview
- Product Description
- Company Profile
Basic Info.
Model NO.
CMS50N
Function 3
Capacity Pulse Scanning & Recording
Measurement
Oxygen Saturation, Pulse Rate
Pr Measuring Range
30bpm~250bpm
SpO2 Measuring Range
0%~100%
Transport Package
Carton
Specification
57mm(L) x 34mm(W) x 31mm(H)
Trademark
CONTEC
Origin
China
HS Code
9018909911
Production Capacity
10000/Week
Product Description
Contec Manufacturer Cms50N Color Finger Pulse Oximeter Adult SPO2 Monitor Model:CMS50N Brand:CONTEC
CMS50N Pulse Oximeter is a portable equipment adopting advanced technology, it mainly checks SpO2 and PR value through the finger, which provides advanced, non-invasive and scientific means for quantitative measurement of oxygen saturation.
CMS50N Pulse Oximeter is applicable for use in plateau area, community healthcare, oxygen bar, Fitness clubs, physical training room, family and medical in stitution, etc.
Features
Can measure SpO2 and Pulse Rate accurately
SpO2 and Pulse Rate display,Pulse Rate waveform and bar graph display
Battery voltage low indication
The display can be changed
Screen brightness adjustable
Physical characteristic
Dimension: 57mm(L) x 34mm(W) x 31mm(H)
Performance
CMS50N Pulse Oximeter is a portable equipment adopting advanced technology, it mainly checks SpO2 and PR value through the finger, which provides advanced, non-invasive and scientific means for quantitative measurement of oxygen saturation.
CMS50N Pulse Oximeter is applicable for use in plateau area, community healthcare, oxygen bar, Fitness clubs, physical training room, family and medical in stitution, etc.
Features
Can measure SpO2 and Pulse Rate accurately
SpO2 and Pulse Rate display,Pulse Rate waveform and bar graph display
Battery voltage low indication
The display can be changed
Screen brightness adjustable
Physical characteristic
Dimension: 57mm(L) x 34mm(W) x 31mm(H)
Performance
SpO2 Measuring Range | 0%~100% |
Screen Resolution | SpO2:1% PR:1bpm |
PR Measuring Range | 30bpm~250bpm |
Accuracy | 70%~100%: ±2% 0%~69%: unspecified ±2bpm or ±2%, whichever is greater. |
Measurement Performance in Weak Filling Condition: | SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ± 2 bpm or ±2%, whichever is greater. |
Resistance to surrounding light: | The deviation between the value mesured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%. |
Working current: | ≤30mA |
Power Supply | two "AAA"batteries |
Safety classification: | type BF applied part |